COMBIFLEX SIKA PDF

The Sikadur®– Combiflex® SG System is a high performance joint sealing system for construction, expansion and connection joints as well as for cracks. Sika® ‘White Tank’ System and refurbishment with the. Sika® -1 Prebagged System. Sikadur® Combiflex® tested under high water-pressure. In conjuction with. The Sikadur®-Combiflex® SG System consists of a flexible Polyolefin (FPO) . Sika® System test: Sikadur®-Combiflex® SG Tapes bonded to each other with.

Author: Vobei Najinn
Country: Cyprus
Language: English (Spanish)
Genre: Science
Published (Last): 21 August 2010
Pages: 63
PDF File Size: 17.42 Mb
ePub File Size: 10.4 Mb
ISBN: 944-5-71490-887-2
Downloads: 27980
Price: Free* [*Free Regsitration Required]
Uploader: Shazshura

Three typical examples of joint profiles using Sikadur-Combiflex are given in Diagrams 1,2 and 3. Protect from direct sunlight. Click here to sign up.

Peel-off Strength sheeting to Sikadur 31 after 6 months immersion in water. This ensures a long life expectancy of such facilities. In practice, the differences in materials, substrates and actual site conditions are such that no warranty in respect of merchantability or of fitness for a particular purpose, nor any liability arising out of any legal relationship xombiflex, can be inferred either from this information, or from any written recommendations, or comhiflex any other advice offered.

All orders are accepted subject to our current terms of sale and delivery which are available on request. In damp conditions use a chalk mark. Especially horizontal expansions joints in floors, decks and roadways have to withstand high mechanical forces and aggressive chemical in- fluences. Wash thoroughly with soap and water.

Both sides must be activated and the sheeting must be left for at least 1 hour before installation. Charcoal Grey when mixed. Dispose of in accordance with local regulations. This increases the longevity of the joints and secures the tightness. In this brochure Sika solutions and concepts for floor and pavement joint sealing as well as other special applications are de- scribed in detail.

Sikadur-Combiflex is designed to be applied to a wide variety of substrates on either side of high movement and irregular joints or where the use of conventional sealing techniques is not possible.

WHERE TO USE Sikadur-Combiflex is designed to be applied to a wide variety of substrates on either side of high movement and irregular joints or where the use of conventional sealing techniques is not possible.

  BALDURS GATE 2 KOMPLETTLSUNG PDF

Activated sheeting must be used within 8 hours. Use of an approved dust respirator, safety goggles and chemical resistant gloves are recommended. In order for a sealant to fulfil its function over the whole lifetime of a building or construction the selection of the right solution and the cor- rect design taking into account all potential influences are essential. Temperature differences result in an The development of our solutions is based on expansion or contraction of the building ele- the latest technologies as well as Sika’s more ments, i.

During this operation, take care to ensure that the epoxy adhesive does not enter the joint. All of them exhibit a long service life even un- der permanent water immersion and resist aggressive liquids used in water treatment plants. Sikadur 31 can either be mixed by hand in small quantities, i.

Apply gentle pressure to eliminate air entrapment, allowing the adhesive to ooze from the edges of the sheeting. Finally, before the Sikadur 31 has set, remove the red pre-applied masking strip from the centre of the Combiflex Hypalon Sheeting and the masking tape if used from both sides of the joint. Colma Cleaner and Hypalon Welding Solvent. Without tooling a smooth surface airplanes, maintenance vehicles and trucks is achieved.

CAD i BIM objekat – Sikadur Combiflex® SG – SIKA

Press the lap together firmly and maintain it in place using clamps or weights for about an hour until the weld is dry. Depending upon the on-site conditions, all lapping and welding of the Combiflex Hypalon Sheeting should be completed before installation. Long-lasting Sika sealants ensure the tightness of the generator housings even under severe weather conditions on sea and seal the joints in concrete segment columns to prevent water penetration and consequent frost damage.

Immediately remove contaminated clothing. Only sealants specifically designed for waste water treatment chemicals this environment are suitable. Usually such joint renovation is done with ly to re-occur. Collect with suitable absorbent material.

This durable solution reduces down 2 Compression profile times of sewage treatment plants. Sika provides different tailor-made solutions for drinking water storage and waste water treatment including sealants, coatings and waterproofing systems. Yet, joint sealants play the major role in keeping a building air and water tight and thus prevent damages with unforeseeable consequen- tial costs.

  ANATHEM BY NEAL STEPHENSON PDF

Cobmiflex Sikadur 31 is a vapour barrier. Our sealants and accessory products are iska designed to ultimately save mon- Why Elastic Sealing?

Bridges, park decks, basements, reservoirs etc. Apply a second 1-mm thick layer of Sikadur 31 on top of the sheeting on either side of the joint as shown in Diagram 4 ensuring that it. Water retaining structures Roofs Parking structures Basements Iron, steel and concrete pipes Between rigid and flexible surfaces Canals. See Packaging below for roll dimensions.

Hence, the maintenance costs are lower thus reduces maintenance costs as well. Hypalon Welding Solvent should be liberally applied to both sides of the lap. To store the biological waste, tight silos and containers are needed. Typical application areas for 2 these highly resistant products are: Open time 1mm film.

Log In Sign Up. The proprietary rights of third parties must be observed. Place the activated Combiflex Hypalon Sheeting over the joint with the red preapplied masking strip facing up and roll it into the Sikadur 31 until the epoxy adhesive comes through the perimeter holes. The surface may be dry or damp, but it must be free of any standing water. Enter the email address you signed up with and we’ll email you a reset link.

Waterproofing Tape System for Cracks and Joints with Sikadur Combiflex® SG

Remove uncured Sikadur 31 from tools with Kwiklean water soluble solvent immediately after use. In order to ensure long term durability and tightness of the newly sealed joint both the substrate surfaces as well as the old sealant remains should be pretreated using the prim- er recommended by Sika. Mix both components thoroughly before use.